
This document describes the networking architecture, communication logic, and operation and maintenance (O&M) methods of the Commercial and Industrial Grid Forming ESS Solution (on-grid, SmartLogger3000), as well as the installation, cable connection, check and preparation before power-on, system power-on commissioning, power-off, and power-on operations. [pdf]

HUAWEI SuperPower Magnetic Power Bank, lightweight and slim, comes with a foldable stand as well as magnetic charging mode, mobile power mode, charger mode, three charging modes to choose from; support for night-time charging mode, at the same time for mobile phones, mobile power efficient energy storage; compatible with different brands of mobile phones, watches and other device; 13 security protection, more peace of mind. [pdf]

This project, developed by Vietnam Electricity (EVN) in collaboration with the Asian Development Bank (ADB), Rocky Mountain Institute (RMI), Global Energy Alliance for People and Planet (GEAPP), and the Vietnam Energy Institute, marks a crucial step towards Vietnam’s target of developing 300MW of energy storage by 2030, as outlined in the latest Eighth Power Development Plan (PDP 8). [pdf]
Sunita Dubey and Hyunjung Lee share how Vietnam is leveraging Battery Energy Storage Systems to stabilize their grid and accelerate the energy transition.
Battery Energy Storage Systems (BESS) play a pivotal role in addressing these challenges by minimising the intermittency of renewables, enhancing grid flexibility, and ensuring reliable power supply. In a significant development, Vietnam Electricity (EVN) has secured approval for its first pilot BESS project with a capacity of 50 MW/50MWh.
At a meeting on Wednesday, the ADB side, represented by Andrew Jeffries, advisor, Energy Transition Mechanism and Partnerships, proposed building a pilot 50MW/50MWh BESS project near Hanoi. A meeting between EVN and ADB to discuss the BESS project, Hanoi, August 14, 2024. Photo courtesy of EVN.
The government anticipates a 10-12% annual surge through 2030 in the nation’s power consumption. This rapidly expanding energy demand presents a significant challenge to Vietnam’s transforming energy landscape, especially considering the urgent need to reduce global emissions and utilise renewable alternatives.
Vietnam is advancing its energy infrastructure towards a greener, more just, and energy-efficient future, simultaneously providing a valuable model inspiring the global drive towards an energy-resilient future.

As a pioneer in zero-carbon quality life, Huawei Smart PV, relying on its profound accumulation of photovoltaic and energy storage technologies and the perfect combination of technological aesthetics and daily life, has launched the "Excellent Photovoltaic Storage, Charging, Network and Cloud" one-stop household smart photovoltaic solution that comprehensively covers core equipment such as inverters, optimizers, energy storage, charging piles, and management systems, aiming to create the zero-carbon home dream for users. [pdf]

Commutation failure is the most common disturbance in thyristor converters during inverter operation which can be triggered by different kinds of faults either the external faults (symmetrical or asymmetrical faults in the AC side, or the DC link to ground fault at the DC link side) [4] or by the internal faults such misfiring control or fault at the valves [5], the AC fault at sending end of the inverter can also leads to commutation failures. [pdf]
With the increasing applications of high-voltage direct current inverters in heavy-load grids, commutation failures (CFs) pose a severe threat to the safe and stable operation of power systems. This study first sorts methods of CF inhibition into different categories and then investigates their effectiveness, adaptability and limitations.
Inverter commutation failures (CFs) in LCC-HVDC systems can cause severe sending-end voltage fluctuations. However, owing to the reliance of analysis methods on average-concept-based power quantities, the transient behavior of the sending-end voltage during inverter CFs remains elusive, hindering the advancement of its suppression strategy.
Introduction Line-commutated converter-based high voltage direct current (LCC-HVDC) technology has been widely used because of advantages such as lower transmission losses and bulk power transmission . However, commutation failure is one of the most common inverter failures in the LCC-HVDC systems.
Simulation results demonstrate the correct analysis and effective suppression method. Inverter commutation failures (CFs) in LCC-HVDC systems can cause severe sending-end voltage fluctuations.
1. Introduction With the advantages of low power loss, large transmission capacity and flexible power regulation, line-commutated converter-based high-voltage direct current (LCC-HVDC) transmission systems have been widely used in cross-regional power transmission and renewable energy integration [, , ].
Capacitor-commutated converters can make the commutation progress easier and faster with the help of capacitors in block A . However, the capacitors result in additional reactive power consumption, harmonics and overvoltage issues that should be eliminated by additional filters and lightning arresters .
We are committed to excellence in solar power plants and energy storage solutions.
With complete control over our manufacturing process, we ensure the highest quality standards in every solar system and energy storage cabinet we deliver.